GA - Circulation Heaters

Liquids and gases with a continuous flow can be heated effectively with compact circulation heaters.

Construction: A heating element is placed in a flow tube from the front. The exchangeable heating element is sealed with threads or flanges. The medium is led into the flow tube, passes the heating element and exits heated.

Temperature control: Circulation heaters require separate temperature regulators. One regulator controls the outlet temperature of the medium, a second regulator limits the temperature of the heating element.

Quotation: For a quotation an exact technical calculation is important. Please describe your planned application and specify medium, volumetric flow-rate, inlet temperature, operating pressure and desired outlet temperature.

Technical Data (Basic Configuration)

flow tube material high-grade steel 1.4541, 1.4571, Inconel, Incoloy
diameter DN 40 ... DN 300
length 350 mm ... 3000 mm
pressure max. 100 bar
connections inlet/outlet flange, thread, welded connection
heating elements material high-grade steel 1.4541, 1.4435, 1.4828, Incoloy 2.48
heating power max. 100 KW , max. 12 W/cm² at the heating element
mains voltage max. 690 V
protection category IP 54, IP 65
temperature sensor NiCr-Ni (K), Pt100, others
electric supply terminal box on the front
fastening screw brackets, adjustable fixing devices
protection against accidental contact optional detachable thermal insulation
   
   
 