Temperature Regulators
Analogous (Single-Channel) Desktop
Regulators
|
|
HT 30 Versatile
Laboratory Regulator with Electronic Outlet for up to
10 A |
If a controlled and careful heating-up is
required, the combination of power controller and PD temperature regulator
produces reliable results.
With this electronic power controller, the
nominal power can be reduced from 100 % to 0 and can thus be adjusted to
individual power requirements. This is especially important at low temperatures
when too much power would cause an overswing of the control circuit.
The digital setpoint adjustment of the
temperature regulator has an accuracy of 1 °C. Due to the adjustable control
amplifier, the regulator can be adapted to the respective controlled system.
Therefore, the accuracy can be kept even if the controlled systems are very
special or different.
When the sensor connection or the sensor element itself is
broken, the device turns off immediately. A control lamp indicates the failure.
With an apparatus clamp, the regulator can be
mounted on a stand. The clamp can be fixed at the rear of the device.
Linear voltage output: For the connection
to a recording instrument, a digital display, etc. ..., the regulator has a
linearized voltage output. The device has a diode plug socket.
Technical Data:
| two-position-regulator |
|
| control system: |
P-PD |
| power control: |
triac |
| switching power at 230 V~: |
2300 W |
| main switch: |
double-pole, luminous |
| degree of accuracy: |
1 % |
| servo amplifier: |
0.5 ... 5 % |
| instantaneous value tap: |
10 mV |
| power control: |
0 ... 100 % |
| safety class: |
I |
| protection category: |
IP 30 (DIN 40 050) |
| interf. suppression: |
N (VDE 0875) |
| mains cable: |
1.5 m |
| case dimensions: |
75 x 115 x 145 mm |
| case material: |
coated steel / aluminum |
|
|
| order no. |
switching
power |
sensor |
| 06 30 01 |
10 A |
NiCr-Ni (K) |
| 06 30 02 |
10 A |
Pt 100 |

|
|
HT 31 Versatile
Laboratory Regulator with Electronic Outlet for up to
16 A |
The laboratory regulator HT 31 has all technical
advantages of the HT 30, but additionally allows switching power up to 16 A.
Technical Data:
| two-position-regulator |
|
| control system: |
P-PD |
| power control: |
triac |
| switching power at 230 V~: |
3600 W |
| main switch: |
double-pole, luminous |
| degree of accuracy: |
1 % |
| servo-amplifier: |
0.5 ... 5 % |
| instantaneous value tap: |
10 mV/°C |
| power control: |
0 ... 100 % |
| safety class: |
I |
| protection category: |
IP 30 (DIN 40 050) |
| interf. suppression: |
N (VDE 0875) |
| main cable: |
1.3 m |
| case dimensions: |
74 x 161 x 136 mm |
| case material: |
coated steel / aluminum |
|
|
| order no. |
switching
power |
sensor |
| 06 31 01 |
16 A |
NiCr-Ni (K) |
| 06 31 02 |
16 A |
Pt 100 |

|
|
Actual Value Display for HT 30 / HT 31 |
Technical Data:
| display: |
LCD |
| case dimensions: |
60 x 80 x 20 mm |
| case material: |
plastic |
| connection: |
with 3-pole socket to HT 30 / HT 31 |
| length connection line: |
1 m |