Temperature Regulators
Capillary Tube Regulator
This capillary tube regulator is suitable for the
simple
temperature monitoring or temperature regulation, for example for frost
protection or for the heating of rainwater gutters.
Technical Data:
| two-position-regulator |
|
| control system: |
P |
| switching hysteresis: |
5 K |
| power control: |
skip contact |
| switching power at 230 V~: |
3600 W AC 1 (16 A) |
| degree of accuracy: |
5 % |
| safety class: |
I |
| protection category: |
IP 65 (DIN 40 050) |
| diameter of terminals: |
2.5 mm˛ |
| case dimensions: |
120 x 160 x 75 mm |
| case material: |
ABS / polycarbonate |
|
| order no. |
range |
| 06 12 01 |
0 ... 40 °C |
| 06 12 02 |
0 ... 85 °C |
| 06 12 03 |
50 ... 250 °C |

|
|
Antifreeze Regulator for Wall
Mounting |
This regulator works after the principle of
liquid expansion and is therefore especially suitable for selflimiting heating tapes
(HBRC / HBRT). A change in temperature causes a change in volume inside
the measuring unit. The resulting expansion of the membrane then activates a
microswitch.
Technical Data:
| setpoint range: |
0 ... 40 °C |
| nominal voltage: |
230 V~ |
| max. switching current: |
16 A / 250 V |
| contact: |
1 change-over contact |
| ambient temperature: |
-20 ... 50 °C |
| switching hysteresis: |
+/- 0.75 K |
| protection category: |
IP 54 (DIN 40 050) |
| sensor system: |
membrane measuring system |
| dimensions: |
145 x 112 x 68 mm |
|
| order no. |
|
| 06 12 20 |
|
| 06 12 21 |
accessory:
protective grating for the capillary against mechanical damage |

Home In General Products Company Profile Contents
Contact
Please send your E-Mail to: info@Horst.de
Copyright © 1997-2005 Horst GmbH. All rights reserved.
Terms of Use.
Last change: 2005-02-25
|